logo
Volume 26, Issue 2 (Spring 2020)                   Intern Med Today 2020, 26(2): 108-117 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Lotfi Marangaloo S, Ariamanesh A S, Aminzadeh B, Abedi H, Montazerabadi A. Comparing Relative Contrast in Three-dimensional Double-echo Steady State With Routine Sequences for a Better Diagnosis of Knee Cartilage Anomalies. Intern Med Today 2020; 26 (2) :108-117
URL: http://imtj.gmu.ac.ir/article-1-3342-en.html
1- Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
2- Department of Orthopedics, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
3- Department of Radiology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
4- Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran. , alireza.montazerabadi@gmail.com
Abstract:   (2605 Views)
Aims This study compared relative contrast values in three-dimensional Double Echo Steady State (DESS) sequences with two flip angles of 40 and 90 degrees and other routine sequences. The obtained data could help to prove the effects of this sequence, compared to the other routine sequences; accordingly, it could be applied for better detection of lesions resulting from cartilage abnormalities.
Methods & Materials Total, 15 patients, including 9 men (14-56 y) and 6 women (36-65 y) with knee pain symptoms were referred to us by an orthopedic physician. All of the investigated patients underwent Magnetic Resonance Imaging (MRI) using DESS sequences with two flip angles of 40 and 90 degrees, as well as STIR , PD, T2, and 3D FLASH. We analyzed the acquired images using the Radiant DICOM Viewer4.6.9 software. We calculated relative contrast values for the selected SAGITAL images per sequence for each patient. The obtained data were analyzed using SPSS.
Findings Friedman and Wilcoxon statistical tests data revealed significant P values (<0.05) for all the sequences examined in this study. The DESS sequence with a flip angle of 90° presented the most relative contrast value with the average score of 77.2667. The FLASH sequence provided the worst result of 3.733 for the relative contrast value.
Conclusion The DESS sequence with 90° flip angle indicated the best relative contrast values and provided the best possible signal from the synovial fluid and the cartilage; therefore, it leads to the better examination of articular cartilage in terms of lesion. Accordingly, the DESS sequence with a flip angle of 90° was the optimal sequence to evaluate cartilage abnormalities among the examined sequences in this study.
Full-Text [PDF 4157 kb]   (1432 Downloads) |   |   Full-Text (HTML)  (2572 Views)  
Type of Study: Original | Subject: Basic Medical Science
Received: 2019/07/2 | Accepted: 2019/12/22 | Published: 2020/06/21

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.